EPIC™ MITRAL AND AORTIC TISSUE VALVES
Exceptional hemodynamic performance, lasting durability, and a design that preserves future valve-in-valve treatment options.
EPIC™ MITRAL AND AORTIC TISSUE VALVES
Exceptional hemodynamic performance, lasting durability, and a design that preserves future valve-in-valve treatment options.
THE FUTURE EXPANDS HERE
The Epic™ Elite valve is CE Mark approved*
Epic™ Elite valves give you the confidence of choosing the precise location of expansion for a future transcatheter aortic or mitral intervention. The expansion zone enables the Epic Elite valve to expand predictably under low pressure (5–9 atm)1 for a larger transcatheter valve implant during a future intervention.
Explore Epic™ Elite Resources
Learn more about future intervention planning and our adaptive cuff technology.
An epic evolution of nature and design
From the start in 1979, our platform of Epic™ mitral and aortic tissue valves has combined the best nature has to offer with advanced engineering. Over the decades, minor adjustments to our legacy valve were added gradually, evolving the Epic™ platform into the innovative porcine tissue valves trusted by physicians today.

Optimized to support future valve-in-valve* interventions
Mitral
- Low stent post height and natural porcine leaflet behavior to not form a "curtain" may reduce risk of obstructing left ventricular outflow tract (LVOT)
- Simplified implantation with ratcheting holder to risk of suture looping while offering one-cut release

Aortic
- Low stent post height may reduce risk of coronary obstruction
- Natural porcine leaflet behavior to not form a "curtain" may reduce need for risky leaflet modification procedures

*Note: The safety and effectiveness of valve-in-valve procedures in Epic™ valves has not been established.
Exceptional durability across patient populations
10 Years
97.3 ± 0.5%
Freedom from
surgery for SVD,
all patient ages
(Epic™ aortic valve)3
10 Years
95.7 ± 2.6%
Freedom from
surgery for SVD,
all patient ages
(Epic™ mitral valve)3
15 Years
98.4 ± 0.8%
Freedom from
surgery for SVD
(Epic™ Supra aortic valve)4
KEY FEATURES
The platform for possibility
The Epic™ platform has been proven over time and defined by strong hemodynamics, intuitive implantability, a future-forward design and more. The platform boasts the low ventricular protrusion in all valve sizes, a flexible polymer stent, individually selected porcine leaflets to ensure optimal coaptation and a flexible sewing cuff designed to minimize both suture drag and paravalvular leak. Now we offer even more for lifetime management with the Epic™ Elite the addition of an expansion zone - for low pressure, predictable expansion in a future intervention.
- Epic™ Elite aortic valve
- PORCINE LEAFLETS
- EXPANSION ZONE
- ADAPTIVE CUFF
- UNIQUE PERICARDIAL SHIELD
- LOW AORTIC PROTRUSION
PORCINE LEAFLETS
Natural leaflet tissue with maximal opening (no muscle bar), complete leaflet coaptation (no central gap), no leaflet curtaining, and less calcification with reduced risk for stroke during reintervention5EXPANSION ZONE
Expands at specific location at low pressures to accommodate a larger transcatheter valve in a future valve-in-valve procedure1*ADAPTIVE CUFF
Engineered to:- Allow maximum flexibility and easy passage through all anatomies
- Prevent paravalvular leaks by sealing in all planes and minimize parachuting resistance when delivering the valve onto the annulus
UNIQUE PERICARDIAL SHIELD
Provides a tissue-to-tissue interface to help prevent the risk of abrasionLOW AORTIC PROTRUSION
Mitigates the risk of coronary obstruction and sinus jailingFlexfit™ polymer stent
- Eases implant
- Accommodates minimally invasive surgery
- Reduces leaflet stress by absorbing shock of each heartbeat
12345PORCINE LEAFLETS
Natural leaflet tissue with maximal opening (no muscle bar), complete leaflet coaptation (no central gap), no leaflet curtaining, and less calcification with reduced risk for stroke during reintervention5
EXPANSION ZONE
Expands at specific location at low pressures to accommodate a larger transcatheter valve in a future valve-in-valve procedure1*ADAPTIVE CUFF
Engineered to:
- Allow maximum flexibility and easy passage through all anatomies
- Prevent paravalvular leaks by sealing in all planes and minimize parachuting resistance when delivering the valve onto the annulus
UNIQUE PERICARDIAL SHIELD
Provides a tissue-to-tissue interface to help prevent the risk of abrasion
LOW AORTIC PROTRUSION
Mitigates the risk of coronary obstruction and sinus jailing
Flexfit™ polymer stent
- Eases implant
- Accommodates minimally invasive surgery
- Reduces leaflet stress by absorbing shock of each heartbeat
*Expansion zone available on sizes 19 mm - 27 mm
- Epic™ Elite mitral valve
- Optimal Leaflet Design and Matching
- Ratcheting Holder
- Flexible Cuff
- Unique Pericardial Shield
- FlexFitTM Polymer Stent
- Low Ventricular Protrusion
- Expansion zone
OPTIMAL LEAFLET DESIGN AND MATCHING
Reduces regurgitation riskRATCHETING HOLDER
Streamlines implant, reduces risk of suture looping, and offers true one cut holder releaseFLEXIBLE CUFF
Mitigates PVL and easily fits patient anatomyUNIQUE PERICARDIAL SHIELD
Provides a tissue-to-tissue interface to help prevent the risk of abrasionFLEXFITTM POLYMER STENT
- Eases implant
- Accommodates minimally invasive surgery
- Reduces leaflet stress by absorbing shock of each heartbeat
LOW VENTRICULAR PROTRUSION
Avoids LVOT obstructionEXPANSION ZONE
Expands at specific location at low pressure to accommodate a larger transcatheter valve in a future valve-in-valve procedure1*
234567Optimal leaflet design and matching
Reduces regurgitation risk
Ratcheting holder
Streamlines implant, reduces risk of suture looping, and offers true one cut holder release
Flexible cuff
Mitigates PVL and easily fits patient anatomy
Unique pericardial shield
Provides a tissue-to-tissue interface to help prevent the risk of abrasion
Flexfit™ polymer stent
- Eases implant
- Accommodates minimally invasive surgery
- Reduces leaflet stress by absorbing shock of each heartbeat
Low ventricular protrusion
Avoids LVOT obstruction
Expansion zone
Expands at specific location at low pressure to accommodate a larger transcatheter valve in a future valve-in-valve procedure1*
*Expansion zone available on sizes 25 mm - 29 mm
- Low Profile Design for Now and Later
Curtaining is a characteristic of bioprosthetic valves in which the leaflets, when opened, stand tall or form a “curtain” between stent posts. Epic leaflets are not prone to curtaining, which may result in less LVOT obstruction.
Leaflet behavior when opened

Epic™ Plus valve with representative transcatheter stent inserted

Mitris Resilia‡ Valve with representative transcatheter stent inserted
‡Indicates a third-party trademark, which is property of its respective owner.
* CE Number 2797
MAT-2630610 v4.0 | Item approved for OUS use only.